OPTICAL FIBER COMPARISON

Compare optical fiber specifications.

Compare G.652.D, G.657.A1, G.657.A2, G.657.B3, OM1, OM3 and OM4 optical fiber on reels. Review source limits and complete test conditions before preparing a bulk fiber RFQ.

SEVEN MODELS · TWO FIBER FAMILIES

Choose a comparison by fiber family.

Single-mode and multimode measurements are shown separately. Every value comes from the existing product reference table; follow a model link to review its source and full specification.

Single-mode comparison

Scroll the table to see all models →
Single-mode fiber — supplier reference specifications
ParameterG.652.DBackbone & metroG.657.A1FTTx & access networksG.657.A2High-density FTTxG.657.B3Indoor FTTH
Attenuation at 1310 nm≤ 0.330 dB/km (standard)≤ 0.350 dB/km≤ 0.350 dB/kmNot listed in reference
Attenuation at 1550 nm≤ 0.185 dB/km (standard)≤ 0.210 dB/km≤ 0.210 dB/km≤ 0.210 dB/km
Cladding diameter125 ± 0.7 μm125 ± 0.7 μm125 ± 0.7 μm125 ± 0.7 μm
Mode field diameter at 1310 nm9.2 ± 0.4 μmNot listed in reference8.6 ± 0.4 μm8.6 ± 0.4 μm
Coating diameter242 ± 7 μm245 ± 10 μm / 200 ± 10 μm242 ± 7 μm / 200 ± 10 μm242 ± 7 μm
Cable cut-off wavelengthNot listed in reference≤ 1260 nmNot listed in referenceNot listed in reference
Published bend-loss testsNot listed in reference
≤ 0.25 dB15 mm radius, 10 turns, 1550 nm
≤ 0.40 dB7.5 mm radius, 1 turn, 1550 nm
≤ 0.15 dB5 mm radius, 1 turn, 1550 nm
≤ 0.45 dB5 mm radius, 1 turn, 1625 nm
Next stepFull specifications →Request a quoteFull specifications →Request a quoteFull specifications →Request a quoteFull specifications →Request a quote

Bend-loss values have different test radii, turns and wavelengths. Compare the stated conditions; these are not finished-cable installation limits.

Multimode comparison

Scroll the table to see all models →
Multimode fiber — supplier reference specifications
ParameterOM1LAN & network extensionsOM3Data centers & LANOM4High-bandwidth data centers
Core diameter62.5 ± 2.5 μm50.0 ± 2.5 μm50.0 ± 2.5 μm
Cladding diameter125.0 ± 1.0 μm125 ± 1.0 μm125 ± 1.0 μm
Attenuation at 850 nm≤ 2.7 dB/km≤ 2.4 dB/km≤ 2.4 dB/km
Attenuation at 1300 nm≤ 0.6 dB/km≤ 0.6 dB/km≤ 0.6 dB/km
Overfilled modal bandwidth at 850 nm≥ 200 MHz·kmNot listed in referenceNot listed in reference
Overfilled modal bandwidth at 1300 nm≥ 500 MHz·kmNot listed in referenceNot listed in reference
Effective modal bandwidth at 850 nmNot listed in reference≥ 2000 MHz·km≥ 4700 MHz·km
Coating diameter245 ± 7 μm245 ± 7 μm245 ± 7 μm
Next stepFull specifications →Request a quoteFull specifications →Request a quoteFull specifications →Request a quote

OFL (overfilled launch) and effective modal bandwidth are different measurements. A value not listed here must be confirmed against the applicable supplier datasheet.

Read the conditions before comparing the numbers.

Bend tests need their full conditions.

Radius, turn count and wavelength belong with every macrobend result. A fiber test is not a finished cable installation limit.

Compare G.657.A1 and G.657.A2 →